 RESEARCH METHODOLOGY OF GREEN BUILDING

 We follow the LEED standing system because it was accepted each over the world and have points which are according to our demand. Now we follow the LEED criteria to get certify our structure.

 

 Figure 1 US Green Building Council Standing System

 instrument PROCESS

 Only needed documents are submitted. After you ’ve submitted your operation and paid the instrument figure, GBCI'll conduct a thorough specialized review. While the type of review you ’ll suffer will vary depending on your sustainability pretensions, the specific requirements of your design.

 • primary Review

 • Final Review

 • Supplemental Review

 

 

 Table1 Details about Fee for LEED Registration

 Operations and conservation freights per structure tableware, Gold and Platinum Level Members Organizational orNon-members

 Registration$,200$,500

 Precertification( performance path projects only-available in Arc)

 Flat figure( per structure)$,000$,000

 Expedited review( reduce from 20- 25 business days to 10- 12, available grounded on GBCI review capacity)

$,000

 instrument Review Rate Minimum Rate Minimum

 Project gross bottom area( banning parking) lower than,000 sq ft

$0.038/ sf$,900$0.046/ sf$,250

 Project gross bottom area( banning parking),000-,99 sq ft

$0.035/ sf$,500$0.042/ sf$,400

 Project gross bottom area( banning parking),000-,999 sq ft

$0.030/ sf$,500$0.036/ sf$,000

 Project gross bottom area( banning parking),000 sq ft or lesser

 Contact GBCI Contact GBCI

 Expedited review( reduce from 20- 25 business days to 10- 12, available grounded on GBCI review capacity)

$,000

 Appeals

 Complex credits

 800 per credit

 Credits

 500 per credit

 Expedited review

 500 per credit

 Formal Inquiries

 design CIRs

 220 per credit

 

Green building works


 

 

 

 Minimum Program Requirement’s

 

 There are seven minimal program conditions which should be full filled before the enrollment process of design. Following are the minimal program conditions

 1. Misbehave with environmental laws

 2. Be a complete, endless structure

. Use a reasonable point boundary

 4. Misbehave with minimal bottom area conditions. A minimum of,000 square bases of gross bottom area must be needed.

 5. Misbehave with minimal residency conditions. The LEED design must be enthralled at least one full- time fellow( FTE) inhabitant

 6. Commit to participating whole- structure energy and water operation data

 7. Misbehave with a minimal structure area to point area rate

 STRATEGIES OF LEED

 In this section different conditions and strategies are bandied to check and estimate different credits mentioned in the chapter.

 Table 2 Maximum Credits Points for each order

 order Maximum Possible Credits

 Energy & Atmosphere( EA) 35

 Sustainable point( SS) 26

 Water Efficiency( WA) 14

 Inner Environmental Quality( IEQ) 15

 Material and coffers( MR) 10

 Total 100

 SUSTAINABLE point( SS)

 Sustainable point order is divided into following sub orders. All the parameters are estimated on the triadic nethermost line values.

 • point design

 • point operation and conservation

 • Transportation

 • Storm water operation

 Table 3 Credits and Points for Sustainable point

 Sustainable point 26

 Credit 1 LEED Certified Design and Construction 4

 Credit 2 Building Exterior and Hardscape Management Plan 1

 Credit 3 Integrated Pest Management, Erosion Control, and Landscape Management Plan 1

 Credit 4 Indispensable exchanging Transportation 3 to 15

 Credit 5 Site Development — cover or Restore Open Habitat 1

 Credit 6 A Storm water Quantity Control 1

 Credit7.1 A Heat Island Reduction —Non-Roof 1

 Credit7.2 Heat Island Reduction — Roof 1

 Credit 8 Light Pollution Reduction 1

 LEED Certified Design and Construction

 To achieve this credit, our design must be formerly certified by the LEED. Bear instrument under at least from one of the following standing systems.

 • LEED for New Construction.

 • LEED for seminaries

 • LEED for Core & Shell with 75 of leasable square footage certified under LEED for marketable Innards.

 

 

 structure Exterior & Hardscape Management Plan

 Plan includes the following strategies that must be apply during the structures performance period at least of 20

 • conservation outfit

 • drawing structure surface

 Integrated Pest Management Plan, Erosion Control and Landscape Management Plan

 out-of-door integrated pest operation to control pest population and help pests from entering structure and requires the following

 • Nonchemical styles, Routine and Inspection

 • exigency conditions and universal announcement defined

 Indispensable Transportation, Public Transportation Access

 Reduce the negative environmental impacts from auto use, including pollution and land development by the use of impulses, structure, and/ or programs. Reduce the number of single inhabitant exchanging passages with conventionally- powered, conventionally fueled vehicles by sharing in following options

 share in a original or indigenous program

 • Survey every regular inhabitant or by arbitrary selection of statistically representative sample check successively for 5 workdays( each day or at the end). In either case, an 80 response rate is needed.

 Site Development, cover or Restore Open Habitat

 Promote biodiversity and give niche by conserving natural areas and restoring damaged areas. During the performance period, insure at least 25 of the point area( not including erecting footmark) or 5 of the point area( including the structure footmark) whichever is lesser is covered with native or acclimated landscaping.